GE THQL2160 Feeder Circuit Breaker, Type THQL, 60 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Pl
PRODUCT OVERVIEW
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire, 70 to 100 amp 6-1/0 Cu or 4 - 1/0 Al AWG wire. UL Listed, HACR rated. 120/240 volt; 10,000 AIR. 1" per pole (2" total).
Product Details
Actuator Type:Quick-Make Quick-Break
Current Rating:60 A
Dimensions:3.28 in L x 2 in W x 2.38 in H
Frame Type:Q-Line
Interrupt Rating:10 kA
Mounting Type:Plug
Number of Phases:1
Number of Poles:2
Operating Frequency:50/60 Hz
Operating Temperature:60 to 75 deg C
Suitable for:Reverse Feed
Terminal Type:Lug
Trip Sensitivity:600 A
Trip Type:Non-Interchangeable
Type:Type THQL
Voltage Rating:120/240 V
Wire Size:8 to 3 8 to 2 AWG
Features
Tin-plated copper stabs create a reliable, permanent and corrosion-resistant connections
Calibration screw is cemented to prevent shifting
Case is made of heat-resistant thermoset for stability and structural integrity
Trips to the center position
View Details
|
6122113 |
GE THQL2160 Feeder Circuit Breaker, Type THQL, 60 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Pl |
2 |
17.99 |
/ EA |
THQL2160 |
|
|

GE THQP120 Feeder Circuit Breaker, Type THQP, 20 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plu
PRODUCT OVERVIEW
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 Cu or #12 to 8 Al AWG wire, 30 to 50 A #8 to 4 Cu or #8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
Product Details
Actuator Type:Toggle
Current Rating:20 A
Dimensions:3.28 in L x 0.5 in W x 2.58 in H
Frame Type:Q-Line
Interrupt Rating:10 kA
Mounting Type:Plug
Number of Phases:1
Number of Poles:1
Operating Frequency:50/60 Hz
Operating Temperature:60 to 75 deg C
Suitable for:Reverse Feed
Terminal Type:Lug
Trip Type:Non-Interchangeable
Type:Type THQP
Voltage Rating:120/240 V
Wire Size:14 to 8 12 to 8 AWG
Features
Tin-plated copper stabs create a reliable, permanent and corrosion-resistant connections
Calibration screw is cemented to prevent shifting
Case made of heat-resistant thermoset for stability and structural
integrity
Trips to the center position
View Details
|
6122311 |
GE THQP120 Feeder Circuit Breaker, Type THQP, 20 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plu |
2 |
7.99 |
/ EA |
THQP120 |
|
|

GE THQP115 Feeder Circuit Breaker, Type THQP, 15 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plu
PRODUCT OVERVIEW
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2 in per pole. UL listed, HACR rated. 15 and 20 A SWD, switching duty rated, suitable for 120 V fluorescent lighting loads. 15 to 25 A #14 to 8 Cu or #12 to 8 Al AWG wire, 30 to 50 A #8 to 4 Cu or #8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
Product Details
Actuator Type:Toggle
Current Rating:15 A
Dimensions:3.28 in L x 0.5 in W x 2.58 in H
Frame Type:Q-Line
Interrupt Rating:10 kA
Mounting Type:Plug
Number of Phases:1
Number of Poles:1
Operating Frequency:50/60 Hz
Operating Temperature:60 to 75 deg C
Suitable for:Reverse Feed
Terminal Type:Lug
Trip Type:Non-Interchangeable
Type:Type THQP
Voltage Rating:120/240 V
Wire Size:14 to 8 12 to 8 AWG
Features
Tin-plated copper stabs create a reliable, permanent and corrosion-resistant connections
Calibration screw is cemented to prevent shifting
Case made of heat-resistant thermoset for stability and structural
integrity
Trips to the center position
View Details
|
6122329 |
GE THQP115 Feeder Circuit Breaker, Type THQP, 15 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plu |
1 |
7.30 |
/ EA |
THQP115 |
|
|

GE THQP240 Feeder Circuit Breaker, Type THQP, 40 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plu
PRODUCT OVERVIEW
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 Cu or 12 to 8 Al AWG wire, 30 to 50 A 8 to 4 Cu or 8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
Product Details
Actuator Type:Toggle
Current Rating:40 A
Dimensions:3.28 in L x 1 in W x 2.58 in H
Frame Type:Q-Line
Interrupt Rating:10 kA
Mounting Type:Plug
Number of Phases:1
Number of Poles:2
Operating Frequency:50/60 Hz
Operating Temperature:60 to 75 deg C
Suitable for:Reverse Feed
Terminal Type:Lug
Trip Type:Non-Interchangeable
Type:Type THQP
Voltage Rating:120/240 V
Wire Size:8 to 4 AWG
Features
Tin-plated copper stabs create a reliable, permanent and corrosion-resistant connections
Calibration screw is cemented to prevent shifting
Case made of heat-resistant thermoset for stability and structural
integrity
Trips to the center position
View Details
|
6122394 |
GE THQP240 Feeder Circuit Breaker, Type THQP, 40 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plu |
2 |
17.09 |
/ EA |
THQP240 |
|
|

GE THQP230 Feeder Circuit Breaker, Type THQP, 30 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plu
PRODUCT OVERVIEW
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 Cu or 12 to 8 Al AWG wire, 30 to 50 A 8 to 4 Cu or 8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
Product Details
Actuator Type:Toggle
Current Rating:30 A
Dimensions:3.28 in L x 1 in W x 2.58 in H
Frame Type:Q-Line
Interrupt Rating:10 kA
Mounting Type:Plug
Number of Phases:1
Number of Poles:2
Operating Frequency:50/60 Hz
Operating Temperature:60 to 75 deg C
Suitable for:Reverse Feed
Terminal Type:Lug
Trip Type:Non-Interchangeable
Type:Type THQP
Voltage Rating:120/240 V
Wire Size:8 to 4 AWG
Features
Tin-plated copper stabs create a reliable, permanent and corrosion-resistant connections
Calibration screw is cemented to prevent shifting
Case made of heat-resistant thermoset for stability and structural
integrity
Trips to the center position
View Details
|
6122410 |
GE THQP230 Feeder Circuit Breaker, Type THQP, 30 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plu |
2 |
17.99 |
/ EA |
THQP230 |
|
|

GE THQP220 Feeder Circuit Breaker, Type THQP, 20 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plu
PRODUCT OVERVIEW
Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. 1/2 in per pole. UL listed, HACR rated. 15 to 25 A 14 to 8 Cu or 12 to 8 Al AWG wire, 30 to 50 A 8 to 4 Cu or 8 to 2 Al AWG wire. 3-9/32 in H x 1/2 in W x 2-3/8 in D. 120/240 V, 10,000 AIR.
Product Details
Actuator Type:Toggle
Current Rating:20 A
Dimensions:3.28 in L x 1 in W x 2.58 in H
Frame Type:Q-Line
Interrupt Rating:10 kA
Mounting Type:Plug
Number of Phases:1
Number of Poles:2
Operating Frequency:50/60 Hz
Operating Temperature:60 to 75 deg C
Suitable for:Reverse Feed
Terminal Type:Lug
Trip Type:Non-Interchangeable
Type:Type THQP
Voltage Rating:120/240 V
Wire Size:14 to 8 12 to 8 AWG
Features
Tin-plated copper stabs create a reliable, permanent and corrosion-resistant connections
Calibration screw is cemented to prevent shifting
Case is made of heat-resistant thermoset for stability and structural integrity
Trips to the center position
Meets NEMA standards
View Details
|
6122477 |
GE THQP220 Feeder Circuit Breaker, Type THQP, 20 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plu |
2 |
17.09 |
/ EA |
THQP220 |
|
|

Square D QO QO140CP Circuit Breaker, Mini, 40 A, 1 -Pole, 120/240 VAC, 48 VDC, Fixed Trip, Plug Moun
PRODUCT OVERVIEW
All QO circuit breakers are equipped with the Visi-Trip(TM) indicator. When a Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between "OFF" and "ON" and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 60 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical
protection.
Product Details
Current Rating:40 A
Dimensions:0.75 in W x 2.91 in D x 3.12 in H
Interrupt Rating:5 10 kA
Mounting Type:Plug
Number of Phases:1
Number of Poles:1
Number Of Spaces:1
Operating Frequency:50/60 Hz
Operating Temperature:104 deg F
Terminal Type:Lug
Trip Type:Fixed
Type:Mini
Voltage Rating:120/240 VAC 48 VDC
Wire Size:8 to 2 AWG
Features
Shielded copper bus bar
Available in single and three phase
Ground bar is included with all main lugs load centers with three mounting locations
Convertible mains let you meet changing job-site requirements
Tangential main service knockouts
Enclosure rotates for top or bottom feed to reduce service cable waste Qwik-Open circuit breaker protection
Exclusive Visi-Trip red indicator
Quick make - quick break mechanism
Plug-on design, easy to install
View Details
|
6190904 |
Square D QO QO140CP Circuit Breaker, Mini, 40 A, 1 -Pole, 120/240 VAC, 48 VDC, Fixed Trip, Plug Moun |
4 |
17.99 |
/ EA |
QO140CP |
|
|

Square D QO QO270CP Circuit Breaker, Mini, 70 A, 2 -Pole, 120/240 VAC, 48 VDC, Plug Mounting, Black
PRODUCT OVERVIEW
The industry leader in circuit protection is easily recognized by the industry's only trip indicator. The red Visi-Trip(TM) Indicator makes it easy to spot a tripped circuit breaker. Compact 3/4 in wide format for one-pole circuit breakers helps minimize panel space and footprint. The Square D(TM) exclusive Qwik-Open(TM) protection is standard on all 15 A and 20 A circuit breakers trip reaction within 1/60th of a second. No other circuit breaker trips faster.
Product Details
Actuator Type:Magnetic Thermal
Color:Black
Current Rating:70 A
Dimensions:1.5 in W x 2.91 in D x 3.12 in H
Interrupt Rating:5 10 kA
Mounting Type:Plug
Number of Phases:1
Number of Poles:2
Number Of Spaces:2
Operating Frequency:50/60 Hz
Operating Temperature:104 deg F
Type:Mini
Voltage Rating:120/240 VAC 48 VDC
Wire Size:8 to 2 AWG
Features
Contains a thermal-magnetic tripping mechanism and has a two-pole common trip
Features a Visi-Trip indicator to easily identify the tripped circuit in the load center
Breaker features a Visi-Trip indicator to easily identify a tripped circuit in the load center
Has a maximum load of 240 volts with a 10,000 AIR and uses a thermal-magnetic tripping mechanism
Compatible with QO load centers, CSED's and NQOD panel board
View Details
|
6191241 |
Square D QO QO270CP Circuit Breaker, Mini, 70 A, 2 -Pole, 120/240 VAC, 48 VDC, Plug Mounting, Black |
6 |
92.99 |
/ EA |
QO270CP |
|
|

Square D QO QO2100CP Circuit Breaker, Mini, 100 A, 2 -Pole, 120/240 VAC, 48 VDC, Plug Mounting, Blac
PRODUCT OVERVIEW
The industry leader in circuit protection is easily recognized by the industry's only trip indicator. The red Visi-Trip(TM) Indicator makes it easy to spot a tripped circuit breaker. Compact 3/4 in wide format for one-pole circuit breakers helps minimize panel space and footprint. The Square D(TM) exclusive Qwik-Open(TM) protection is standard on all 15 A and 20 A circuit breakers trip reaction within 1/60th of a second. No other circuit breaker trips faster.
Product Details
Actuator Type:Magnetic Thermal
Color:Black
Current Rating:100 A
Dimensions:1.5 in W x 2.91 in D x 3.5 in H
Interrupt Rating:5 10 kA
Mounting Type:Plug
Number of Phases:1
Number of Poles:2
Number Of Spaces:2
Operating Frequency:50/60 Hz
Operating Temperature:104 deg F
Type:Mini
Voltage Rating:120/240 VAC 48 VDC
Wire Size:4 to 2/0 AWG
Square D CAFI circuit breakers feature time saver diagnostics to help find circuit issues faster
UL-listed and now available in QO single-pole circuit breakers with 15 and 20 A ratings
Square D CAFI circuit breakers remember their last trip-ground fault, arc fault, overload and short circuit
QO plug-on neutral CAFI circuit breakers are designed for use in QO plug-on neutral load centers
View Details
|
6191381 |
Square D QO QO2100CP Circuit Breaker, Mini, 100 A, 2 -Pole, 120/240 VAC, 48 VDC, Plug Mounting, Blac |
3 |
119.99 |
/ EA |
QO2100CP |
|
|

Bussmann BP/S-6-1/4 Plug Fuse, 6.25 A, 125 V, 10 kA Interrupt, Low Voltage, Time Delay Fuse
PRODUCT OVERVIEW
Heavy-duty. Protects critical motor circuits or motors that cycle On/Off frequently. Body sizes prevent interchangeability and dangerous over-fusing. Dual element design, industrial/commercial-grade, spring loaded to provide short circuit and overload protection. Non-transferring. Will thread into SA adapters. UL Listed. 125 V maximum. 10,000 AIR.
Product Details
Current Rating:6.25 A
Element Type:Dual
Fuse Type:Low Voltage Time Delay
Interrupt Rating:10 kA
Length:19-3/16 in
Rejection/ Non- Rejection:Rejection
Voltage Rating:125 V
Features
Heavy-duty, dual-element, time delay rejection base fuse
Use to protect critical motor circuits or motors that cycle On/Off frequently
Non-interchangeable body
An industrial or commercial-grade product with dual-element construction These fuses thread into SA adapters
Industrial strength, featuring an exclusive dual-element construction
This spring-loaded design provides excellent short circuit and overload protection
More time delay than the medium-duty type SL fuses in order to better protect industrial motors and critical residential circuits
View Details
|
6195879 |
Bussmann BP/S-6-1/4 Plug Fuse, 6.25 A, 125 V, 10 kA Interrupt, Low Voltage, Time Delay Fuse |
3 |
7.99 |
/ EA |
BP/S-6-1/4 |
|
|

Bussmann BP/S-8 Plug Fuse, 8 A, 125 V, 10 kA Interrupt, Low Voltage, Time Delay Fuse
PRODUCT OVERVIEW
Heavy-duty. Protects critical motor circuits or motors that cycle On/Off frequently. Body sizes prevent interchangeability and dangerous over-fusing. Dual element design, industrial/commercial-grade, spring loaded to provide short circuit and overload protection. Non-transferring. Will thread into SA adapters. UL Listed. 125 V maximum. 10,000 AIR.
Product Details
Current Rating:8 A
Element Type:Dual
Fuse Type:Low Voltage Time Delay
Interrupt Rating:10 kA
Length:6-13/32 in
Rejection/ Non- Rejection:Rejection
Voltage Rating:125 V
Features
Heavy-duty, dual-element, time delay rejection base fuse
Use to protect critical motor circuits or motors that cycle On/Off frequently
Non-interchangeable body
An industrial or commercial-grade product with dual-element construction These fuses thread into SA adapters
Industrial strength, featuring an exclusive dual-element construction
This spring-loaded design provides excellent short circuit and overload protection
More time delay than the medium-duty type SL fuses in order to better protect industrial motors and critical residential circuits
View Details
|
6195903 |
Bussmann BP/S-8 Plug Fuse, 8 A, 125 V, 10 kA Interrupt, Low Voltage, Time Delay Fuse |
2 |
12.95 |
/ EA |
BP/S-8 |
|
|

Bussmann BP/SL-15 Plug Fuse, 15 A, 125 V, 10 kA Interrupt, Time Delay Fuse
PRODUCT OVERVIEW
Threaded fuse type, porcelain threads. Heat absorbing metal bead on element link for time delay. Passes motor overload starting currents without needlessly opening. Voltage rating of 125 V maximum. Rejection base. UL Listed.
Product Details
Current Rating:15 A
Element Type:Single
Fuse Type:Time Delay
Interrupt Rating:10 kA
Length:5-1/2 in
Rejection/ Non- Rejection:Rejection
Voltage Rating:125 V
Features
Medium-duty time delay rejection base fuse
Has ability to withstand typical motor starting surges
Use in residential or light-duty motor circuits
These fuses thread into SA adapters
View Details
|
6196059 |
Bussmann BP/SL-15 Plug Fuse, 15 A, 125 V, 10 kA Interrupt, Time Delay Fuse |
3 |
5.39 |
/ EA |
BP/SL-15 |
|
|

Bussmann BP/SL-25 Plug Fuse, 25 A, 125 V, Time Delay Fuse, 10 kA Interrupt
PRODUCT OVERVIEW
Threaded fuse type, porcelain threads. Heat absorbing metal bead on element link for time delay. Passes motor overload starting currents without needlessly opening. Voltage rating of 125 V maximum. Rejection base. UL Listed.
Product Details
Current Rating:25 A
Element Type:Single
Fuse Type:Time Delay
Interrupt Rating:10 kA
Rejection/ Non- Rejection:Rejection
Voltage Rating:125 V
Features
Medium-duty time delay rejection base fuse
Has ability to withstand typical motor starting surges
Use in residential or light-duty motor circuits
These fuses thread into SA adapters
View Details
|
6196133 |
Bussmann BP/SL-25 Plug Fuse, 25 A, 125 V, Time Delay Fuse, 10 kA Interrupt |
5 |
10.35 |
/ EA |
BP/SL-25 |
|
|

Bussmann BP/SRU Series Box Cover Unit, Gray, Specifications: 1/2 hp
PRODUCT OVERVIEW
Box cover units for standard electrical boxes provide supplemental fuse protection for small motor circuits and other loads requiring overcurrent protection below that of the branch circuit overcurrent protective device. Versions are available for a fused outlet, switch use with SA adapters and S or SL Type fuses may prevent fuse cover from closing. Not recommended for use with MB-15 Edison base circuit breaker or plain circuit that fit standard sized electrical boxes.
Product Details
Color:Gray
Dimensions:2.26 in L x 2.6 in W x 4.2 H
Specifications:15 A 2-1/4 in Handy Box Fuse Holder/Three prong Receptacle 1/2 hp 125 VAC
Features
A low-cost method of controlling and protecting small motors when used with Bussmann Series type T dual-element fuses
Low-cost supplemental protection and disconnection of 125 V or less, single-phase circuits
View Details
|
6196232 |
Bussmann BP/SRU Series Box Cover Unit, Gray, Specifications: 1/2 hp |
3 |
32.55 |
/ EA |
BP/SRU |
|
|

Bussmann BP/T-8 Plug Fuse, 8 A, 125 V, 10 kA Interrupt, Plastic Body, Low Voltage, Time Delay Fuse
PRODUCT OVERVIEW
Used for circuits where motors frequently turn on and off. A simple link element for short circuits and dangerous overloads plus a Series connected element which lets the harmless overload starting currents of motors pass without opening.
Product Details
Body Material:Plastic
Current Rating:8 A
Element Type:Dual
Fuse Type:Low Voltage Time Delay
Interrupt Rating:10 kA
Voltage Rating:125 V
Features
Heavy-duty time delay plug fuse
Use to protect critical motor circuits or motors that cycle On/Off frequently
An industrial or commercial-grade product with dual-element construction More time delay than the medium-duty type TL fuses in order to better protect industrial motors and critical residential circuits
These fuses thread into fuse receptacles and box cover units
Industrial strength, featuring an exclusive dual-element construction
This spring-loaded design provides excellent short circuit and overload protection
View Details
|
6196323 |
Bussmann BP/T-8 Plug Fuse, 8 A, 125 V, 10 kA Interrupt, Plastic Body, Low Voltage, Time Delay Fuse |
2 |
16.99 |
/ EA |
BP-T-8 |
|